MEPC.107(49) certified 15ppm bilge alarms for vessels across the UAE from Rivertrace, Deckma Hamburg, and Panasia.
Niaar supplies 15ppm bilge alarms vessel operators and marine engineers specify for continuous monitoring of oil content in bilge water before overboard discharge. Our range draws from Rivertrace, Deckma Hamburg. Panasia — three brands whose bilge alarm technology supports MARPOL pollution prevention compliance worldwide.
A 15ppm bilge alarm continuously analyses the oil content of water passing through a vessel's oily water separator, automatically alerting crew and stopping overboard discharge if oil content exceeds the 15ppm limit IMO Resolution MEPC.107(49) establishes. Therefore, bilge alarm reliability directly determines whether a vessel can legally discharge bilge water at sea.
Alarm selection involves measuring cell technology, data logging capability, and integration with the vessel's existing oily water separator system. Because of this, we work with three established brands offering proven, MEPC.107(49) certified bilge alarm technology. As a result, engineers specifying 15ppm bilge alarms products can get exactly the monitoring capability their compliance program requires.
Every order ships with type approval documentation confirming compliance with IMO Resolution MEPC.107(49) requirements. Specifically, this lets engineers confirm the alarm meets applicable flag state and port state control requirements. Additionally, our technical team supports both new installations and alarm replacement during scheduled equipment renewal.
Rivertrace supplies the widely deployed SMART Bilge system, using a proprietary detector array technology that analyses heavy fuel oil, diesel. Emulsions simultaneously without requiring re-calibration between oil types.
Their SMART CELL measuring cell includes onboard flash memory, a real-time clock. Dual switch inputs meeting MEPC.107(49) data logging requirements. Furthermore, Rivertrace offers an automatic cell cleaning option, addressing optical fouling, the leading cause of bilge monitor malfunction.
Deckma Hamburg, supplying oil-in-water monitors since the early 1970s, offers the OMD-24 and OMD-2008 series widely deployed across global commercial shipping. Furthermore, their units include onboard data logging storing up to 18 months of discharge history. Both compliance documentation and port state control inspections. Consequently, Deckma's long operating history gives operators confidence in proven, field-tested reliability.
Panasia rounds out our range with additional bilge alarm technology for vessels with specific budget or technical requirements. In practice, our team helps specifiers compare all three brands against exact vessel type and compliance requirements.
IMO Resolution MEPC.107(49) establishes the technical performance standards every certified 15ppm bilge alarm must meet before installation.
Port state control familiarity with specific brands varies by region, an occasional practical consideration during international vessel operation.
Data logging review supports both internal environmental compliance tracking and the discharge history port state control inspectors commonly request.
Our team helps facilities understand data export and reporting capability across each specific brand. Genuine inspection readiness without scrambling for historical records.
Cell cleaning frequency significantly affects alarm reliability, since optical fouling remains the leading cause of bilge monitor malfunction and false readings.
Our team helps facilities establish appropriate cleaning schedules, whether manual or automatic, protecting measurement accuracy across the alarm's entire operational life.
Calibration verification against certified reference samples confirms ongoing accuracy, supporting both internal compliance confidence and external port state control inspections.
Our technical team can connect facilities with appropriate calibration services, ensuring bilge alarm equipment maintains certified accuracy throughout extended vessel service.
Our broader catalogue covers comprehensive bilge alarm systems programs supporting MARPOL bilge monitoring compliance. As trusted suppliers serving marine pollution control facilities, we maintain genuine oil water separator alarm and bilge discharge monitor stock, supporting IMO bilge alarm requirements with reliable marine oil sensor technology.
Niaar's 15ppm bilge alarms supply backs vessel operators across the UAE with access to all three major brands. Finally, our 15ppm bilge alarms technical team manages procurement from initial specification through calibration and commissioning support.
| Specification | Details |
|---|---|
| Detection Method | Infrared/UV Fluorescence/Light Scattering |
| Measurement Range | 0-100 ppm (standard), 0-1000 ppm (extended) |
| Accuracy | ±1 ppm at 15 ppm setpoint |
| Response Time | 10-30 seconds typical |
| Alarm Setpoint | 15 ppm (adjustable 10-20 ppm) |
| Sample Flow Rate | 1-3 liters/minute |
| Operating Temperature | -10°C to +55°C |
| Power Supply | 24VDC/110VAC/220VAC (model dependent) |
| Output Signals | 4-20mA, RS485, Modbus, relay contacts |
| Display Type | LCD/LED with backlight |
| Data Storage | Minimum 18 months continuous logging |
| Enclosure Rating | IP67 (sensor), IP65 (control unit) |
| Certification | IMO MEPC.107(49), MEPC.1/Circ.642 |
| Calibration Interval | 6-12 months (classification society dependent) |