Niaar supplies Manual Call Points Break Glass from E2S, Klaxon, Moflash, and Qlight — EN54-11 certified fire alarm call points, break glass alarm devices, addressable call points, and emergency call points Dubai for UAE and GCC projects.
Niaar supplies Manual Call Points Break Glass from leading manufacturers including E2S, Klaxon, Moflash, and Qlight. Manual Call Points Break Glass are fire alarm activation devices. Allow a person discovering a fire to immediately trigger the fire alarm system.
Breaking the glass element or pressing the button activates the call point. Niaar provides full procurement support for Manual Call Points Break Glass and all emergency call points Dubai across the UAE and GCC.
Fire alarm activation using a break glass alarm is the most fundamental manual fire alarm trigger. First, the occupant breaks the glass element of the call point using the integral hammer or a key. This completes the alarm circuit and triggers the fire alarm panel. Second, break glass alarm devices are available in resettable and non-resettable versions.
Resettable break glass call points use a replaceable glass element. Third, fire alarm activation devices from E2S, Klaxon, Moflash, and Qlight are designed to EN 54-11. This is the European standard for manual call points in fire detection systems.
Furthermore, break glass alarm devices are available in standard, weatherproof. Explosion proof versions for indoor, outdoor, and hazardous area installation. Therefore, Manual Call Points Break Glass from Niaar cover every installation environment at UAE commercial and industrial facilities.
Emergency call points Dubai are installed at regular intervals throughout buildings and industrial facilities. First, UAE Civil Defence requires emergency call points Dubai to be installed adjacent to all fire exits, at each floor of stairwells. At strategic locations throughout occupied buildings. Second, call point UAE installation height is typically 1.4 metres above floor level for accessibility to all building occupants.
Third, emergency call points Dubai from E2S and Klaxon are available in red finish with white lettering. They comply with UAE Civil Defence signage and colour-coding requirements.
Furthermore, emergency call points Dubai are connected to the fire alarm control panel on the same signalling circuit as fire detectors. They trigger the same alarm response as an automatic detector activation. Therefore, Manual Call Points Break Glass from Niaar are correctly installed and connected for UAE fire safety system compliance.
EN54-11 certified call points are independently tested to the European standard for manual call points. First, EN54-11 certified call points must activate reliably across a wide temperature range and under simulated environmental stress conditions. Second, addressable call points from E2S and Klaxon communicate their device address to the fire alarm control panel.
This allows the exact activated call point location to be displayed. Third, EN54-11 certified call points carry a CE mark and a certificate from a notified body. These are required for UAE Civil Defence system approval.
Furthermore, addressable call points from E2S and Qlight integrate with addressable fire alarm systems from Notifier, Apollo. Other major panel manufacturers. Therefore, Manual Call Points Break Glass from Niaar in EN54-11 certified configuration meet all UAE fire safety equipment and regulatory requirements.
Manual fire alarm activation for industrial applications uses call points designed for harsh environments. First, explosion proof manual call points from E2S and Klaxon are ATEX Zone 1 certified for installation in UAE oil and gas and petrochemical hazardous areas. Second, manual fire alarm call points for industrial application are available in stainless steel and GRP enclosures with IP66 or higher ingress protection.
Third, manual fire alarm devices for offshore and marine applications carry marine type approval from Lloyd's Register or Bureau Veritas.
Niaar manages Manual Call Points Break Glass procurement from project specification through device selection, EN54-11 compliance review, and delivery. Niaar works with E2S, Klaxon, Moflash, and Qlight to supply emergency call points Dubai and break glass alarm devices for all UAE and GCC fire safety projects.
Niaar manages Manual Call Points Break Glass procurement from project specification through device selection, EN54-11 compliance, and delivery. Niaar works with E2S, Klaxon, Moflash, and Qlight to supply emergency call points Dubai and break glass alarm devices for all UAE and GCC fire safety projects.
Furthermore, fire safety equipment for manual alarm activation from Niaar includes both building-grade and industrial-grade products. Submit an RFQ via Niaar.net for these detectors, emergency call points Dubai, break glass alarm devices, EN54-11 certified call points. Addressable call points across UAE and GCC projects.
Technical specifications for Manual Call Points (Break Glass) encompass critical performance parameters ensuring reliable emergency activation across diverse installation environments:
| Specification | Details |
|---|---|
| Activation Method | Break-glass element with manual reset or replaceable frangible component |
| Operating Force | 3.5-4.5 kg activation force compliant with EN54-11 standards |
| Contact Configuration | Single pole changeover, double pole, or addressable protocol |
| Environmental Protection | IP24, IP65, IP67 options for indoor/outdoor/marine installations |
| Operating Temperature | -30°C to +70°C extended range for harsh environments |
| Housing Material | UV-stabilized polycarbonate, stainless steel, or aluminum alloy |
| Mounting Options | Surface mount, flush mount, or pedestal configurations |
| Terminal Capacity | 1.5-2.5mm² wire acceptance with screw or cage-clamp terminals |
| Certifications | EN54-11, UL38, FM3210, CE marked, ATEX/IECEx for hazardous areas |
| Dimensions | 95-110mm height × 95-110mm width × 45-60mm depth typical |
Manual call points comply with comprehensive international safety standards including EN54-11 (Fire Detection and Alarm Systems - Manual Call Points), UL38 (Standard for Manually Actuated Signaling Boxes), and FM3210 approval protocols. For example, ATEX Directive 2014/34/EU and IECEx certifications enable deployment in Zone 1 and Zone 2 hazardous atmospheres common in UAE oil and gas operations. As a result, CE marking ensures conformity with European Low Voltage Directive (LVD) and EMC requirements. Devices meet UAE Civil Defence regulations, NFPA 72 (National Fire Alarm and Signaling Code), BS5839 (Fire Detection and Alarm Systems for Buildings), and ISO 7240-11 international standards. Next, IP protection ratings comply with IEC 60529 ingress classification, while environmental testing follows IEC 60068 climatic stress protocols. Finally, RoHS and REACH compliance ensures environmental responsibility across supply chains.